The microcomputer control system automatically detects pressure during crimping and has dual safety protection.
The temperature sensor automatically stops the tool when the temperature exceeds 60 ℃ during long-term operation, and the fault signal sounds, indicating that the tool cannot continue working until the temperature drops to normal.
If there is a deviation from the set operating pressure or low battery level, an audible signal will be emitted and the red display screen will flash.
This tool is equipped with a dual piston pump, which is characterized by fast access to the connecting material and automatic transfer to high pressure through slow crimping.
One click control to press the trigger to start working, releasing halfway means stopping pressurization, and fully releasing means the piston returns to its original position.